Specification C-Stat 11-ZW | C-Stat 17-ZW
Thermostat
Power Supply 2 x AA Batteries
Contact type Micro-disconnection
Wiring configuration Voltage free c/o contacts (SPDT)
Temperature differential 0.5°C
Temperature accuracy +/- 0.5°C to 21°C
Standards BS EN 60730-2-9
Dimensions (WxHxD) 120mm x 100mm x 26.5mm
Weight 0.3kg (approx)
Enclosure Flame retardant thermoplastic
Ingress protection IP30
Pollution degree Degree 2
Insulation class Class II (Double Insulated)
Temperature range 0°C to 40°C
Transmitter Frequency 868 MHZ
Receiver Category Category 3
Power Class Class B
Receiver
Power Supply 230V AC 50Hz
Contact Type Micro-disconnection
Voltage Free
Contact Current Rating 3 (1) Amps 230V AC
Insulation Class Double Insulated
Rated Impulse Voltage Cat 2 2500V
Pollution Degree Degree 2
Enclosure Protection Flame retardant thermoplastic
Dimensions 86 x 86 x 36.25mm
15
Seitenansicht 14