Electrical Connections
WARNING: ISOLATE THE MAINS SUPPLY BEFORE COMMENCING INSTALLATION
As the HRT4-ZW is a wireless product with no electrical connections all electrical wiring will be
made to the ASR-ZW receiver.
All necessary electrical connections should now be made. Flush wiring can enter from the rear
through the aperture in the backplate.
The mains supply terminals are intended to be connected to the supply by means of fixed wiring.
The receiver is mains powered and requires a 3 Amp fused spur.
The recommended cable size is 1.Omm
2
.
The receiver is double insulated and does not require an earth connection, an earth connection
block is provided on the backplate for terminating any cable earth conductors. Earth continuity must
be maintained and all bare earth conductors must be sleeved. Ensure that no conductors are left
protruding outside the central space enclosed by the backplate.
Two example circuit diagrams for typical boiler installations are shown opposite. These diagrams are
schematic and should be used for guidance only.
Please ensure that all installations comply with the current IEE regulations and the boiler
manufacturers installation instructions.
For reasons of space and clarity not every connection has been included and the diagrams have
been simplified, for instance some earth connections have been omitted.
N L 1 2 3 4
230V 50V COMM OFF ON
Internal
Electronics
ASR-ZW Receiver internal wiring diagram
The receiver has Voltage Free contacts. A link between
Live and terminal 2 is required for mains Voltage
applications.